Description
Technical Data
Type | Size range [mm] |
Tightening torque MA [Nm] |
Fy permitted per Beam Clip [kN] |
Shear force load capacity Fz per set = 4 Beam Clips [kN] |
---|---|---|---|---|
M12 S | 1 – 30 | 85 | 26,3 | 12,0 * |
M16 S | 4 – 40 | 150 | 32,0 | 13,6 * |
* The specified data relate to the worst case with flange thicknesses 30 mnm (M12) or 40 mm (M16) as well as a coefficient of adhesion µadhesion = 0,20.
A possibly operating tensile force Fy isn’t included.
Material: | Steel, HCP |